{"product_id":"ugreen-pdu-power-strip-c13-outlets-90519","title":"UGREEN PDU Power Strip, C13 Outlets (90519)","description":"\u003cstyle\u003e\/* UGREEN India product description layout *\/\n.ugd-story { --ugd-acc: #169b45; --ugd-ink: #14181c; --ugd-text: #4a5258; --ugd-line: #e3e6e8; --ugd-soft: #f4f5f6; color: var(--ugd-ink); font: 16px \/ 1.7 -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Arial, sans-serif; width: 100%; max-width: 1200px; margin: 0px auto; container-type: inline-size; text-align: left; overflow-wrap: anywhere; }\n.ugd-story * { box-sizing: border-box; }\n.ugd-story :is(h2, h3, h4, p, figure, ul, ol, dl, dd) { margin: 0px; padding: 0px; }\n.ugd-story :is(h2, h3, h4) { color: var(--ugd-ink); font-weight: 700; letter-spacing: -0.02em; text-transform: none; }\n.ugd-story h2 { font-size: clamp(26px, 4.2cqi, 42px); line-height: 1.15; }\n.ugd-story h3 { font-size: clamp(21px, 3cqi, 30px); line-height: 1.2; }\n.ugd-story h4 { font-size: 18px; line-height: 1.35; }\n.ugd-story p { color: var(--ugd-text); font-size: 16px; line-height: 1.7; }\n.ugd-story p + p { margin-top: 10px; }\n.ugd-story img { display: block; width: 100%; height: auto; border: 0px; border-radius: 14px; background: var(--ugd-soft); }\n.ugd-story a { color: var(--ugd-acc); }\n.ugd-story .ugd-eyebrow { display: block; color: var(--ugd-acc); font-size: 12px; font-weight: 700; letter-spacing: 0.14em; text-transform: uppercase; margin-bottom: 10px; }\n.ugd-story .ugd-section { padding: clamp(36px, 6cqi, 64px) 0px; border-top: 1px solid var(--ugd-line); }\n.ugd-story .ugd-head { max-width: 720px; margin-bottom: 24px; }\n.ugd-story .ugd-head p { margin-top: 10px; }\n.ugd-story .ugd-hero { display: grid; grid-template-columns: 1.1fr 1fr; gap: clamp(20px, 4cqi, 48px); align-items: center; background: var(--ugd-soft); border-radius: 20px; padding: clamp(22px, 4cqi, 48px); }\n.ugd-story .ugd-hero p { margin-top: 14px; font-size: 17px; }\n.ugd-story .ugd-chips { display: flex; flex-wrap: wrap; gap: 8px; margin-top: 18px; list-style: none; }\n.ugd-story .ugd-chips li { background: rgb(255, 255, 255); border: 1px solid var(--ugd-line); border-radius: 999px; padding: 5px 12px; font-size: 13px; font-weight: 600; color: var(--ugd-ink); }\n.ugd-story .ugd-stats { display: grid; grid-template-columns: repeat(4, 1fr); gap: 0px; margin: 16px 0px 0px; border: 1px solid var(--ugd-line); border-radius: 16px; overflow: hidden; }\n.ugd-story .ugd-stats div { padding: 16px 18px; border-left: 1px solid var(--ugd-line); }\n.ugd-story .ugd-stats div:first-child { border-left: 0px; }\n.ugd-story .ugd-stats b { display: block; font-size: clamp(20px, 2.8cqi, 28px); line-height: 1.1; color: var(--ugd-ink); }\n.ugd-story .ugd-stats span { display: block; font-size: 13px; color: var(--ugd-text); margin-top: 4px; }\n.ugd-story .ugd-nav { display: flex; gap: 8px; overflow-x: auto; padding: 16px 0px; margin: 0px; list-style: none; scrollbar-width: none; }\n.ugd-story .ugd-nav::-webkit-scrollbar { display: none; }\n.ugd-story .ugd-nav a { flex: 0 0 auto; display: block; padding: 7px 14px; border-radius: 999px; background: var(--ugd-soft); color: var(--ugd-ink); font-size: 13px; font-weight: 600; text-decoration: none; white-space: nowrap; }\n.ugd-story .ugd-tests { display: grid; grid-template-columns: repeat(4, 1fr); gap: 12px; list-style: none; }\n.ugd-story .ugd-tests li { background: var(--ugd-soft); border-radius: 14px; padding: 16px; }\n.ugd-story .ugd-tests b { display: block; font-size: clamp(24px, 3.2cqi, 32px); line-height: 1; color: var(--ugd-acc); }\n.ugd-story .ugd-tests strong { display: block; margin-top: 8px; font-size: 16px; }\n.ugd-story .ugd-tests span { display: block; font-size: 13px; color: var(--ugd-text); margin-top: 2px; line-height: 1.45; }\n.ugd-story .ugd-note { font-size: 13px !important; margin-top: 12px; }\n.ugd-story .ugd-feature { display: grid; grid-template-columns: 1fr 1fr; gap: clamp(18px, 4cqi, 48px); align-items: center; }\n.ugd-story .ugd-feature + .ugd-feature { margin-top: clamp(28px, 5cqi, 56px); }\n.ugd-story .ugd-feature.ugd-rev figure { order: 2; }\n.ugd-story .ugd-feature ul { margin-top: 14px; padding-left: 20px; }\n.ugd-story .ugd-feature li { color: var(--ugd-text); margin-top: 6px; }\n.ugd-story .ugd-uses { display: grid; grid-template-columns: repeat(3, 1fr); gap: 12px; }\n.ugd-story .ugd-uses figcaption { font-weight: 600; margin-top: 8px; font-size: 15px; }\n.ugd-story .ugd-box { display: grid; grid-template-columns: 1fr 1fr; gap: clamp(18px, 4cqi, 40px); align-items: start; }\n.ugd-story .ugd-box ol { columns: 2; column-gap: 24px; padding-left: 22px; }\n.ugd-story .ugd-box li { color: var(--ugd-text); break-inside: avoid; margin-bottom: 6px; }\n.ugd-story .ugd-specs { display: grid; grid-template-columns: repeat(2, 1fr); border-top: 1px solid var(--ugd-line); }\n.ugd-story .ugd-specs div { display: grid; grid-template-columns: 42% 1fr; gap: 12px; padding: 12px 0px; border-bottom: 1px solid var(--ugd-line); }\n.ugd-story .ugd-specs div:nth-child(2n+1) { padding-right: 24px; }\n.ugd-story .ugd-specs dt { font-weight: 600; font-size: 14px; }\n.ugd-story .ugd-specs dd { color: var(--ugd-text); font-size: 14px; }\n.ugd-story details { border-bottom: 1px solid var(--ugd-line); }\n.ugd-story summary { cursor: pointer; list-style: none; padding: 16px 32px 16px 0px; font-weight: 600; font-size: 16px; position: relative; }\n.ugd-story summary::-webkit-details-marker { display: none; }\n.ugd-story summary::after { content: \"+\"; position: absolute; right: 4px; top: 12px; font-size: 22px; color: var(--ugd-acc); }\n.ugd-story details[open] summary::after { content: \"–\"; }\n.ugd-story details p { padding: 0px 0px 16px; }\n.ugd-story .ugd-trust { display: grid; grid-template-columns: repeat(4, 1fr); gap: 12px; list-style: none; background: var(--ugd-ink); border-radius: 18px; padding: clamp(18px, 3cqi, 28px); }\n.ugd-story .ugd-trust li { color: rgb(255, 255, 255); font-size: 14px; line-height: 1.45; }\n.ugd-story .ugd-trust b { display: block; color: rgb(255, 255, 255); font-size: 15px; }\n.ugd-story .ugd-trust span { color: rgb(185, 194, 199); }\n@container (max-width: 700px) {\n.ugd-story .ugd-hero, .ugd-story .ugd-feature, .ugd-story .ugd-box { grid-template-columns: 1fr; }\n.ugd-story .ugd-hero figure { order: -1; }\n.ugd-story .ugd-feature.ugd-rev figure { order: 0; }\n.ugd-story .ugd-stats { grid-template-columns: 1fr 1fr; }\n.ugd-story .ugd-stats div:nth-child(3) { border-left: 0px; }\n.ugd-story .ugd-stats div:nth-child(n+3) { border-top: 1px solid var(--ugd-line); }\n.ugd-story .ugd-tests { grid-template-columns: 1fr 1fr; }\n.ugd-story .ugd-uses { grid-template-columns: 1fr 1fr; }\n.ugd-story .ugd-uses figure:last-child { grid-column: 1 \/ -1; }\n.ugd-story .ugd-specs { grid-template-columns: 1fr; }\n.ugd-story .ugd-specs div:nth-child(2n+1) { padding-right: 0px; }\n.ugd-story .ugd-trust { grid-template-columns: 1fr 1fr; }\n}\n@container (max-width: 380px) {\n.ugd-story .ugd-box ol { columns: 1; }\n}\n.ugd-story .ugd-feature.ugd-noimg { grid-template-columns: 1fr; max-width: 780px; }\n.ugd-story .ugd-stats.ugd-s2 { grid-template-columns: 1fr 1fr; }\n.ugd-story .ugd-uses figcaption, .ugd-story figure figcaption { color: var(--ugd-ink); }\n.ugd-story .ugd-box.ugd-noimg { grid-template-columns: 1fr; }\n.product-details rte-formatter \u003e .ugd-wide { max-width: none !important; width: 100% !important; }\n.product-details rte-formatter \u003e .ugd-story.ugd-wide { max-width: 1200px !important; }\n.ugd-story ul.ugd-nav,.ugd-story ul.ugd-chips,.ugd-story ul.ugd-trust{list-style:none!important;padding-left:0!important;margin-left:0!important}.ugd-story ul.ugd-nav li,.ugd-story ul.ugd-chips li,.ugd-story ul.ugd-trust li{list-style:none!important}.ugd-story ul.ugd-nav li::before,.ugd-story ul.ugd-chips li::before,.ugd-story ul.ugd-trust li::before,.ugd-story ul.ugd-nav li::marker,.ugd-story ul.ugd-chips li::marker{content:none!important;display:none!important}\n\u003c\/style\u003e\u003cdiv class=\"ugd-story ugd-wide\"\u003e\n\u003cheader class=\"ugd-hero\"\u003e\u003cdiv\u003e\n\u003ch2\u003eUGREEN PDU Power Strip, C13 Outlets\u003c\/h2\u003e\n\u003cp\u003eOrganise power distribution inside a server or network cabinet with the UGREEN 90519 PDU. It provides eight IEC C13 outlets in a rack-mountable metal housing, with a master switch for controlling the connected equipment together. Rotating brackets allow the strip to fit horizontally or vertically in a compatible 19-inch cabinet.\u003c\/p\u003e\n\u003cul class=\"ugd-chips\"\u003e\u003cli\u003eUGREEN · SKU 90519\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/header\u003e\u003cdiv class=\"ugd-stats\"\u003e\n\u003cdiv\u003e\n\u003cb\u003e8 × IEC C13\u003c\/b\u003e\u003cspan\u003eOutlets\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003e10 A maximum\u003c\/b\u003e\u003cspan\u003eRated current\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003e250 V AC\u003c\/b\u003e\u003cspan\u003eRated voltage\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003e1.8 m\u003c\/b\u003e\u003cspan\u003ePower cord length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cnav\u003e\u003cul class=\"ugd-nav\"\u003e\n\u003cli\u003e\u003ca href=\"#ugd-features\"\u003eFeatures\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#ugd-specs\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#ugd-faqs\"\u003eFAQs\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/nav\u003e\u003cdiv class=\"ugd-section\" id=\"ugd-features\"\u003e\n\u003cdiv class=\"ugd-head\"\u003e\n\u003cspan class=\"ugd-eyebrow\"\u003eFeatures\u003c\/span\u003e\u003ch3\u003eWhat it does well.\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ugd-feature ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eKey features\u003c\/h4\u003e\n\u003cp\u003e\u003cb\u003eEight IEC C13 outlets.\u003c\/b\u003e Connect compatible IEC equipment leads in one organised row for a tidier cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDouble-pole master switch.\u003c\/b\u003e The switch disconnects both live and neutral conductors together.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFlexible rack mounting.\u003c\/b\u003e Adjustable mounting brackets suit horizontal or vertical placement in a compatible 19-inch rack.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMetal housing.\u003c\/b\u003e An aluminium-alloy enclosure and internal copper busbar support cabinet power distribution.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-feature ugd-rev ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eA practical guide to choosing and using it\u003c\/h4\u003e\n\u003cp\u003e\u003cb\u003ePlan a tidier cabinet power layout.\u003c\/b\u003e A rack power strip is most useful when it is planned alongside the equipment layout. Place the PDU where each compatible lead can reach its outlet without being stretched across ventilation openings. Group leads by device, label both ends and keep the switch accessible. This makes a later equipment change easier to trace and reduces the need to disturb unrelated connections.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMatch the whole connection path.\u003c\/b\u003e Start with the supply or UPS, then check the PDU input plug, output outlets and equipment leads in that order. An IEC outlet name describes a connector shape; it does not confirm that a particular UPS socket, cable or appliance is suitable. For each connection, check the plug format and electrical rating as well as the available physical space.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eUnderstand the shared capacity.\u003c\/b\u003e The PDU rating applies to the complete strip. Eight outlets provide connection positions, but they do not create eight separate power budgets. Add the requirements of all connected equipment and allow for how the equipment behaves during startup. The supply circuit, UPS and connecting leads may impose a lower limit than the strip itself, so plan around the complete installation.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMake maintenance easier.\u003c\/b\u003e Choose the horizontal or vertical bracket position before connecting equipment. Allow enough room to grip each plug and to route cables without tight bends at the outlets. Where a network or server shutdown would interrupt work, follow the equipment shutdown procedure before using the common switch. Treat the switch as a shared power control for everything attached to the PDU.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-feature ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eWhere it fits\u003c\/h4\u003e\n\u003cp\u003e\u003cb\u003eNetwork cabinet.\u003c\/b\u003e Arrange power for switches and other compatible network equipment close to the installed hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eServer rack.\u003c\/b\u003e Keep compatible equipment leads together while leaving access to the master switch.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-box ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eWill it work with your setup?\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eIEC C13 outlets accept matching IEC C14 plugs on suitable equipment leads.\u003c\/li\u003e\n\u003cli\u003eDesigned for compatible 19-inch cabinets; allow room for plug depth and cable bends.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-box ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eSetup and everyday use\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eCheck the PDU input connector against your UPS or supply connection before ordering.\u003c\/li\u003e\n\u003cli\u003ePosition the strip where plugs, cables and the master switch remain accessible.\u003c\/li\u003e\n\u003cli\u003eConnect correctly rated equipment leads and keep the combined load within the PDU, source and cable ratings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-feature ugd-rev ugd-noimg\"\u003e\u003cdiv\u003e\u003ch4\u003eA closer look\u003c\/h4\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-box ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eBefore you buy\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThese are IEC equipment outlets, so ordinary Indian appliance plugs do not connect directly.\u003c\/li\u003e\n\u003cli\u003eThe master switch controls the connected equipment together. This PDU does not provide battery backup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"ugd-feature ugd-noimg\"\u003e\u003cdiv\u003e\n\u003ch4\u003eInside the box\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003e1 × UGREEN 90519 PDU with attached power cord and mounting brackets\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ugd-section\" id=\"ugd-specs\"\u003e\n\u003cdiv class=\"ugd-head\"\u003e\n\u003cspan class=\"ugd-eyebrow\"\u003eSpecifications\u003c\/span\u003e\u003ch3\u003eAt a glance.\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdl class=\"ugd-specs\"\u003e\n\u003cdiv\u003e\n\u003cdt\u003eBrand \/ SKU\u003c\/dt\u003e\n\u003cdd\u003eUGREEN 90519\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eModel\u003c\/dt\u003e\n\u003cdd\u003eCD297\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eOutlets\u003c\/dt\u003e\n\u003cdd\u003e8 × IEC C13\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eRated current\u003c\/dt\u003e\n\u003cdd\u003e10 A maximum\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eRated voltage\u003c\/dt\u003e\n\u003cdd\u003e250 V AC\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eRated power\u003c\/dt\u003e\n\u003cdd\u003e2500 W maximum at rated voltage\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003ePower cord length\u003c\/dt\u003e\n\u003cdd\u003e1.8 m\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eMounting\u003c\/dt\u003e\n\u003cdd\u003e19-inch cabinet; horizontal or vertical\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eHousing\u003c\/dt\u003e\n\u003cdd\u003eAluminium alloy\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ugd-section\" id=\"ugd-faqs\"\u003e\n\u003cdiv class=\"ugd-head\"\u003e\n\u003cspan class=\"ugd-eyebrow\"\u003eFAQs\u003c\/span\u003e\u003ch3\u003eQuestions buyers ask.\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat equipment is this PDU intended for?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat plugs fit the eight output sockets?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs the 2500 W rating available at every socket?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I connect it to a UPS?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes it provide battery backup or automatic voltage conversion?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow does the double-pole master switch work?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the PDU be installed vertically as well as horizontally?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow much reach does the attached cable provide?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I use adapters to connect any appliance?\u003c\/summary\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat should I check before purchasing for an existing rack?\u003c\/summary\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cscript\u003e(function(){function m(){var s=document.querySelector(\".ugd-story,.ht-story,.ava-story\");if(!s)return;var d=s.closest(\".product-block--description\");var a=document.querySelector(\"article.product--outer\");if(!d||!a||d.closest(\".ugd-fullwrap\"))return;var w=document.createElement(\"div\");w.className=\"ugd-fullwrap\";w.style.cssText=\"max-width:1200px;margin:40px auto 0;padding:0 24px;box-sizing:border-box;width:100%\";w.appendChild(d);a.parentNode.insertBefore(w,a.nextSibling);}if(document.readyState!==\"loading\")m();else document.addEventListener(\"DOMContentLoaded\",m);})();\u003c\/script\u003e","brand":"UGREEN","offers":[{"title":"Default Title","offer_id":46255550398563,"sku":"90519","price":4750.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0581\/3780\/4899\/files\/ugreen-90519-pdu-c13-product.webp?v=1790150585","url":"https:\/\/ugreenindia.com\/hi\/products\/ugreen-pdu-power-strip-c13-outlets-90519","provider":"Ugreen India","version":"1.0","type":"link"}